Chimney Seismic Retrofit in Lomita for Brick Chimneys
Booking This Service
Say whether the fireplace is metal or brick and what it is doing. We call back to set the visit.
The Service, Part by Part
A tall brick stack on a wood-framed house moves differently from the house in a quake, and the part above the roof is the most exposed. The choices are an angle-iron brace back to the rafters, steel bands at the floor and ceiling lines, or swapping the brick above the roof for a framed chase around listed metal pipe. We judge the brick and mortar first, then price the choices that fit your stack.
Which Chimneys Need It and Which Do Not
Start with what your chimney is made of, because that decides whether this page applies. A house with a factory-built fireplace and a framed chase has a chimney made of wood, siding and light steel pipe. It is fastened to the house frame along its length and moves with the house in a quake, so it is not the falling hazard people picture. Its weak points in shaking are smaller ones: pipe joints that can pull apart, firestops that can shift, and a cap that can loosen. A brick chimney is the opposite. It is heavy, it stands on its own footing, and above the roof it is a tall column with little holding it sideways. In strong shaking the top tends to snap off near the roofline and fall onto the roof, a walkway or a car. The 1987 and 1994 quakes showed that across Los Angeles County, and many older houses near Lomita still have brick stacks of that age.
Owners of brick stacks have three routes to less risk, picked by the stack's height, its condition and how the fireplace is used. On the roof, an angled steel brace can anchor the upper stack to rafters so it has something to push against besides its own mortar. Inside the house, steel straps can bind the stack to the joists at each level it passes. Or the top can come off altogether, taken down to about the roof, with a lighter chimney above it: a framed chase with a listed metal flue, or a flue that serves a new gas appliance. Bracing and strapping only help when the brick itself is sound. Where the mortar has turned soft or the stack has already cracked, adding steel to it does little, and the scope will say so plainly. We describe these options in general terms here and settle the details on the roof.
What the Visit Checks and the Scope Lists
A retrofit visit starts on the roof and ends in the attic. Outside, we measure how far the stack rises above the roof, look at its width and the number of flues, tap and probe the mortar for soft joints, and look for old cracks that were filled after an earlier quake. We check the crown, the cap and the flashing, because a retrofit that leaves those failing is half a job. Inside, we look at how the chimney passes the framing, whether there is anything to anchor steel to, and how the fireplace below is used. Where a house has both a brick chimney and a prefab unit, we check the prefab pipe and its firestops too, because the visit is a chance to make the whole roof safer at once. Then you get a written scope with each option laid out in its own section.
Each option in the scope shows what would be done, what it covers and what it leaves, and what it costs. Bracing and strapping list the steel, the anchoring points and any brick repair needed first. Taking the stack down lists how far, what replaces it, how the roof is closed or the chase framed, and what happens to the fireplace below. We do not quote codes, promise rebates or say any method makes a chimney quake proof; we describe what each does to the risk. Retrofit work has no list price on this site, because no two stacks need the same steel or the same depth of removal. If you are selling or buying, the scope can go to both agents. Use the form to tell us the house, what the chimney is built of if you know, and whether the fireplace is still used.
How Lattimore Chimney Solutions Handles It
Plate First
Maker and model recorded before any part is named
Listed Parts
Factory-built units repaired with parts approved for them
Brick by Its Rules
Masonry stacks get mortar, crown and tile work suited to their age
Price on Paper
Each line priced and signed before work starts
Chimney Seismic Retrofit in our focus cities
Pick a city to read how this service applies to the houses there, metal units and brick alike.
Nothing on the list under that name. Check the spelling or try a ZIP.
More Services
Chimney Sweep
Creosote and soot brushed from tile flues and listed metal pipe alike, with rods and heads chosen for the flue you have.
Learn More →Chimney Inspection
A Level 1 visual check of a brick stack or a metal chimney system, each finding written against the part it concerns.
Learn More →Chimney Repair
Repairs to brick stacks and framed chases, scoped outward from the part that failed instead of from a standard package.
Learn More →Fireplace Inspection
We identify the fireplace as masonry or factory-built, read its label, then check box, panels, screen and clearances against that listing.
Learn More →Fireplace Repair
Cracked refractory panels, warped dampers, loose screens and parted pipe joints on factory-built units, fixed with parts named for that model.
Learn More →Chimney Level 2 Inspection
Video of the flue from the box to the top termination, plus the attic run and framing the chimney passes through, for $370.
Learn More →Chimney Cap Installation
Caps for tile flues and the listed tops factory-built chimneys need, measured on the roof and priced before fitting.
Learn More →Chimney Flashing Repair
Leaks where the roof meets a brick stack or a framed chase, proven with water before any metal is cut or resealed.
Learn More →Chimney Masonry Repair
Brick, mortar and crowns on masonry stacks, priced face by face so sound sections stay as they are.
Learn More →Chimney Rebuilds
Brick stacks relaid, or replaced above the roof with a framed chase around listed metal pipe, with both routes priced.
Learn More →Fireplace Cleaning
Firebox, panels, screen and glass cleaned from the room side, with a light hand on refractory and painted metal.
Learn More →Gas Fireplace Cleaning
A yearly service for sealed gas units: burner, pilot, media, glass seal and outside termination cleaned and checked.
Learn More →Gas Fireplace Repair
Gas fireplaces that ignore the remote, lose the pilot or burn a sooty flame, metered and repaired with parts for that model.
Learn More →Fireplace Remodel
New faces, mantels and hearths around a masonry or factory-built box, with that box's clearance rules built into the design.
Learn More →Fireplace Inserts
Gas inserts approved for your existing box, with liner, gas hookup and startup, priced $2,650 to $5,300 installed.
Learn More →Pellet Stove Repair
Pellet units metered at the igniter, auger motor, blowers and safety switches, then fixed with parts made for that stove.
Learn More →Wood Stove Repair
Freestanding and insert wood stoves repaired at the door, glass, baffle, brick and pipe, with wall clearances checked.
Learn More →Gas Logs
Log sets matched to the opening and the fireplace listing, with gas line, valve and lighting option priced up front.
Learn More →Chimney Crown Repair
Mortar crowns on brick stacks sealed while sound, or recast in concrete when not, so rain stays off the top courses.
Learn More →Dryer Vent Cleaning
Lint packed in the duct from dryer to outside hood cleared, crushed foil connectors swapped and the hood flap freed.
Learn More →Chimney Liner Installation
Stainless liners for cracked tile flues and new inserts, matched in diameter to the stove, insert or gas unit they will vent.
Learn More →Chimney Leak Repair
Water at the ceiling, the firebox or the chase traced to one source, then repaired for $530 to $3,150 by what failed.
Learn More →Chimney Waterproofing
A breathable repellent on sound brick above the roof, put on after repairs so it protects masonry instead of hiding cracks.
Learn More →Chimney Damper Repair
Dampers that stick, warp or no longer seal, repaired in place or replaced with a top-sealing damper at the flue exit.
Learn More →Chimney Chase Cover
Rusted or sagging tops on framed chases replaced with stainless or galvanized covers cut to fit and cross-broken to shed rain.
Learn More →